Fluxgate AC/DC CATIII 300V DIN rail current sensor

We're here to help

Talk to an expert today.
Our friendly team of highly trained specialists will quickly assist you.

Get a quote technical support +61 2 8283 6945

Description

The Flux Gate AC/DC Current Sensor is a high accuracy DIN rail mounted sensor designed for reliable measurement of both AC and DC currents in low voltage electrical systems. Using closed loop flux gate technology, the sensor provides stable and linear current measurement with low hysteresis, low temperature drift, and excellent long term accuracy for demanding monitoring applications.

Suitable for power quality monitoring, EV charging, battery systems, solar applications, industrial automation, railway signalling, and UPS systems, the sensor delivers a proportional mV output compatible with power quality analysers, PLCs, SCADA systems, and other instruments with mV inputs. It is optimised for use with the Miro PQ45 and Miro PCM platforms.

Key Features

Part Number To be used with
1ADCFLUXG100A MIRO PQA, Power Quality Logger and Analyser
MIRO PCM, Point Condition Monitor
Any compatible instrument with mV input

Download Brochure

Technical Information

General Characteristics
DC Accuracy 1% of reading ± 120 mA
Aperture Size 11.4 x 20.8 mm
Mating Connector 4-position 5.08 mm terminal block plug
Insulation Category CAT III 300 V reinforced insulation
Ingress Protection IP30
Product Mass 110 g
Nominal Operating Temperature Range -25°C to +65°C
Power Indicator LED Colour Green
Power Supply Reverse Polarity Protection Yes
Mounting ‘Top Hat’ style DIN rail, TH 35-7.5
Parameter Symbol Min Typ Max Unit
Nominal Measuring Range -100 +100 A
Maximum Measuring Range -150 +150 A
Maximum Measuring Range when used with Miro PQ45 -120 +120 A
Nominal Sensitivity 6.25 mV/A
Parameter Symbol Min Typ Max Unit
Power Supply 11.8 12 13.2 V DC
Current Consumption1 100 mA
Additional Error Due to Earth’s Magnetic Field 0.12 A
Load Resistance 10
Frequency Bandwidth (-3 dB) 10 kHz
Temperature Drift of Measurement2 200 ppm/°C
Output Temperature Drift at 0 A 250 μV/°C
Hysteresis Error 0.16
(0.16)
A
(% Range)
Notes:
1. At ±100 A primary current.
2. Percentage of reading characterised at 10 A.